| Device name | Device model | Contact | ||||
|---|---|---|---|---|---|---|
| vacuum pomp | Buchi Vac V-500 | |||||
|
The Büchi Vac V-500 is a vacuum pump suitable for evacuating laboratory equipment to a vacuum of Tags: Others |
||||||
| Scintillation counter, Scintillometer | Tri-Carb 2910 TR | |||||
|
The Tri-Carb 2910 TR is a computer controlled benchtop liquid scintillation analyzer (LSA) capable of analyzing small amounts of alpha, beta, and gamma radioactivity. It has a robust sample changer mechanism with an electrostatic controller and a double light sealing shutter for maximum stability, keeping the photomultiplier tube detector on even during sample change. It is featured with TR-LSCfor high sensitivity, low background counting and increasing sample throughput. Tags: Others |
||||||
| Flow Cytometer | BD FACSCalibur | |||||
|
The BD FACSCalibur system (Flow cytometery cell analyzer) is equiped with 2 lasers: 15 mW, 488 nm, Tags: Cytometry |
||||||
| Fast Protein Liquid Chromatography (FPLC) system | AKTA FPLC System (Amersham Biosciences) | |||||
|
ÄKTApurifier is an automated liquid chromatography system. Consists of a compact separation unit, a personal computer running UNICORN™ control system version 5.31 and: a fraction collector, a monitor and conductivity measurement (included for ÄKTApurifier UPC). Tags: HPLC/FPLC |
||||||
| Ultra-low temperature freezer | MDF-U53V ultra-low temperature freezer (Sanyo) | |||||
|
The Sanyo MDF-U53V is an ultra-low temperature freezer with a temperature range of -50°C to -90°C, a 519-liter capa city. Designed for preserving biological samples and cells. it features a microprocessor-controlled system with alarms for temperature deviation, a robust cascade refrigeration system for stable temperature. Tags: Sample Storage |
||||||
| Shaking incubators | Multitron Pro shaking incubators (Infors HT) | |||||
|
The Infors HT Multitron Pro is a large capacity incubator shaker, for cell culture, protein expression, fermentation, or microbial processing. The instrument features precise, reliable heating and shaking. Its capacity is approximately 200 liters, with a speed range of 20-400 rpm and a shaking throw of 25 mm. The maximum temperature is 60°C. Tags: Culture, Shaking, Incubation |
||||||
| Fluorescence stereomicroscope with camera | Zeiss Axio Zoom V16 with Axiocam 705 mono camera | |||||
|
Fluorescence stereomicroscope Axio Zoom V16 (Zeiss) equipped with an Axiocam 705 mono camera allows high-resolution imaging of fluorescent and brightfield samples. The system includes interchangeable 1.0×, 1.5×, and 2.3× objectives, providing flexible magnification and depth of field suitable for detailed visualization of C. elegans and other small biological specimens. Tags: Imaging |
||||||
| Centrifuge 5430 R | Centrifuge 5430 R | |||||
|
The Centrifuge 5430 R combine the best features of a microcentrifuge (compact size) with the versatility of a multipurpose centrifuge. These high-speed centrifuges accommodate rotors for Eppendorf tubes and PCR strips, as well as rotors for microplates and 15 or 50 mL conical tubes.Additional Eppendorf QuickLock® rotors are now available in the rotor range, including 48-place rotors (1.5 mL or 2.0 mL), a 16-place rotor for 5.0 mL Eppendorf Tubes, and a swing-bucket rotor (24 x 1.5 mL or 2.0 mL). Tags: Centrifugation |
||||||
| Millipore Direct Detect IR Spectrometer System Lab | Millipore Direct Detect IR Spectrometer System Lab | |||||
|
The Direct Detect® Infrared Spectrometer, developed by EMD Millipore (now part of Merck), is a system that uses infrared (IR) spectroscopy to quantify proteins, lipids, and detergents by measuring amide bonds in protein chains and the carbon-hydrogen bonds in aliphatic chains of lipids and detergents. It requires only 2 µL of sample, provides results in minutes, and works directly on an "assay-free" PTFE membrane card, Tags: Spectrofotometer |
||||||
| Life Technologies E-Gel Imager UV Light Base | Life Technologies E-Gel Imager UV Light Base | |||||
|
The Life Technology E-gel Imager is a compact imaging system ideal for capturing gels incorporating fluorescent DNA stains such as Invitrogen SYBR Safe stain and Invitrogen SYBR Green stain, as well as for E-Gel EX agarose gels. This imaging system is flexible to your lab’s needs, consisting of a scientific grade, 1.3-megapixel camera hood, and interchangeable bases. This imager comes with an E-Gel Image adaptor base, designed to provide power to either the E-Gel iBase/E-Gel Safe Imager base Tags: Imaging |
||||||
| Monolith® NT.115 Microscale Thermophoresis | Monolith® NT.115 Microscale Thermophoresis | |||||
|
Microscale thermophoresis allows to monitor a great variety of molecular interactions rapidly and with a very low sample consumption, by measuring optically the mobility of macromolecules in a microscopic temperature gradient generated in a capillary tube. Monolith N115 detects extrinsic fluorophores emitting at blue and red wavelengths (Monolith NT 115). Microscale Thermophoresis (MST) detects changes in the hydration shell of molecules and measures biomolecular interactions under close to nati Tags: Isothermal Electrophoresis |
||||||
| Labconco FreeZone Freeze Dryers | Labconco FreeZone Freeze Dryers | |||||
|
Dehydration is an important process for the Tags: Others |
||||||
| Labconco FreeZone® 4.5 Liter Freeze Dry System | Labconco FreeZone® 4.5 Liter Freeze Dry System | |||||
|
The Labconco FreeZone® 4.5 Liter Freeze Dry System is designed for laboratory lyophilization procedures. It is CFC-free so it will not endanger the environment. Freeze drying is an important process in sample preparation and for the preservation and storage of biologicals, pharmaceuticals and foods. Of the various methods of dehydration, freeze drying (lyophilization) is especially suited for substances that are heat sensitive. Tags: Others |
||||||
| Sorvall Legend X1R Centrifuge | Sorvall Legend X1R Centrifuge | |||||
|
Sorvall Legend X1R Centrifuge Tags: Centrifugation |
||||||
| NanoDrop 2000c Spectrophotometer | NanoDrop 2000c Spectrophotometer | |||||
|
Thermo Scientific NanoDrop™ 2000c Spectrophotometers measure 0.5- 2 ul samples with high accuracy and reproducibility. The NanoDrop 2000c model offers the convenience of both the NanoDrop patented sample retention technology and a traditional cuvette for sample measurements. The sample retention system employs surface tension to hold the sample in place between two optical fibers. This enables the measurement of very highly concentrated samples without the need for dilutions. Tags: Spectrofotometer |
||||||
| Lambda 950 UV-Vis NIR Spectrophotometer | Lambda 950 UV-Vis NIR Spectrophotometer | |||||
|
The Lambda 950 UV/Vis/NIR is a double beam, double monochromator, all-reflecting optical system which operates in the ultraviolet (UV), visible (vis) and near infra-red (NIR) spectral range. Deuterium and tungsten Halogen light sources. Automatic source change occurs during monochromator slewing; and, programmed optical filters also perform automatic filter change. Tags: Spectrofotometer |
||||||
| Lambda 25 UV-Vis Spectrophotometer | Lambda 25 UV-Vis Spectrophotometer | |||||
|
PerkinElmer’s Lambda 25 UV/Vis system increases productivity by mimicking the QA workflow and generating high quality results time after time. The Lambda systems are easy to operate and deliver results you can rely on with a minimum of operator training – it’s easy to develop simple, robust methods and ensure they are followed flawlessly. It is used for the qualitative identification of a compound in a solution, as well as for the quantitative identification of a substance in a solution. Tags: Spectrofotometer |
||||||
| XP2U Microbalance | XP2U Microbalance | |||||
|
Mettler Toledo XP2U Microbalance Tags: Others |
||||||
| analytical balance XS 205 DualRange | analytical balance XS 205 DualRange | |||||
|
An analytical balance is a highly precise measuring instrument used to determine the mass of small samples with a high degree of accuracy and precision. It is commonly used in scientific research, analytical chemistry, and quality control settings, where minuscule variations in weight can have significant effects. With a capacity ranging from 22 to 520 g and readability from 0.001 to 1 mg, METTLER TOLEDO analytical balances are perfectly suited to sensitive applications, such as density determin Tags: Others |
||||||
| Azure 400 | 400 | |||||
|
The Azure 400 is a flexible fluorescent imager that enables three-color fluorescent detection for dyes in the visible range. Tags: Imaging |
||||||